The bulletin of the Yamaguchi Medical School Volume 69 Issue 3-4
published_at 2022-12
Clinical outcomes of the GORE VIABAHN VBX balloonexpandable covered stent in aortoiliac occlusive disease and acute limb ischemia
Abstract Objectives: This study examined the short-term outcomes of endovascular therapy (EVT) with the GORE VIABAHN VBX (VBX) which is a balloon-expandable covered stent in patients with aortoiliac occlusive disease (AIOD) and acute limb ischemia (ALI). Methods: This was a single-center retrospective review of patients with AIOD and ALI who underwent EVT with the VBX between December 2018 and January 2021. Primary, assisted, and secondary patency rates were assessed, along with 30-day mortality rates. Results: Twenty-two patients underwent EVT with the VBX; 18 patients had AIOD, whereas 4 had ALI. The incidence of TransAtlantic Intersociety Classification II D lesions was 50% (n=9). Technical success was 100%. One patient with unilateral common iliac artery stenosis developed an intraoperative dissection of the distal edge of the VBX, which required an additional self-expanding VIABAHN stent on the distal edge of the VBX. The primary patency rate at 24 months was 100%. No patients required additional target vessel treatment at a median follow-up of 10 months (range, 1-27). EVT was also successful in the four patients with ALI, who had no complications of the target vessel. Conclusion: The present study demonstrated that EVT with the VBX is effective for AIOD and ALI.
Creator Keywords
aortoiliac occlusive disease
acute limb ischemia
balloon-expandable covered stent
VIABAHN VBX