コンテンツメニュー

Fukada Mitsuo

Affiliate Master Yamaguchi University

On the New Method for Measuring Water Level and Small Pressure Difference

Memoirs of the Faculty of Engineering, Yamaguchi University Volume 31 Issue 1 Page 179-188
published_at 1980
KJ00000156349.pdf
[fulltext] 859 KB
Title
水位, および極微小差圧の新計測法について
On the New Method for Measuring Water Level and Small Pressure Difference
Creators Fukada Mitsuo
Creators Saitou Takashi
Creators Osaki Katashi
Creators Tanaka Yasuhiro
Source Identifiers
Some of the elementary principles of water level and pressure difference measurement devices are discussed, and these devices were practically made according to the principle. One of these devices is float-type water level meter equipped with swing-arm mechanism which indicate the water surface elevation after magnification. On the other hand, two types of difference meter were made for determining very small difference in pressure precisely. These devices are both very simple in principle and in construction. 1. an inverted bell type difference meter 2. an balance type difference meter by means of these simple devices, the pressure difference was measured very accurately in a different way than ever before, taking note of the weight difference of fluid in manometers rather than the head. These devices, in combination with pitot tube and pitot-static tube, made able to measure local variations of velocity and pressure in the thin flow on the rough wall.
Subjects
土木工学 ( Other)
Languages jpn
Resource Type departmental bulletin paper
Publishers 山口大学工学部
Date Issued 1980
File Version Version of Record
Access Rights open access
Relations
[ISSN]0372-7661
[NCID]AN00244228
Schools 工学部