Calculation of Coulomb Force to a Conductor Based on the Analysis of Electric Field Strength
        Memoirs of the Faculty of Engineering, Yamaguchi University Volume 33 Issue 1
        Page 121-126
        
    published_at 1982
            Title
        
        電界解析を用いた導体作用クーロン力の計算
        Calculation of Coulomb Force to a Conductor Based on the Analysis of Electric Field Strength
        
    
                
                    Creators
                
                    Tanibe Toshiyuki
                
                
            
            
                
                    Creators
                
                    Adachi Takayoshi
                
                
            
            
                
                    Creators
                
                    Saeki Setsuo
                
                
            
    
        
            Source Identifiers
        
    
        Vibration of a transmission-line conductor is set up by corona discharge on water drops hanging beneath the conductor under rainy weather. This corona-induced vibration of a transmission-line conductor has become more serious problem owing to the rise of transmission voltage. To make the mechanism of coronainduced vibration clear theoretically, it is important to investigate force to a conductor. As the first step, calculation of coulomb force caused by space charge is described in this paper. The calculation model is the co-axial cylindrical electrodes, and the inner conductor has a knife edge which shames hanging water drops. In computing coulomb force, the analysis method of electric field strength is used. The calculation of electric field strength is performed with the method of successive approximation. In general, it is difficult to determine boundary conditions in calculation of corona electric field. Therefore, in order to determine the boundary condition for the space charge density, we adopted electric field strength in the vicinity of the tip of the knife edge. Using electric field strength at the surface of the inner conductor, which is calculated in the manner described above, it is able to compute coulomb force working the conductor. Coulomb force was calculated under various conditions such as applied voltage, diameter of a conductor, and length of projection. As a result, it was showed to be able to treat of force to a conductor quantitatively. And we obtained a guide to analyse corona-induced vibration theoretically.
        
        
            Languages
        
            jpn
    
    
        
            Resource Type
        
        departmental bulletin paper
    
    
        
            Publishers
        
            山口大学工学部
    
    
        
            Date Issued
        
        1982
    
    
        
            File Version
        
        Version of Record
    
    
        
            Access Rights
        
        open access
    
    
            Relations
        
            
                
                
                [ISSN]0372-7661
            
            
                
                
                [NCID]AN00244228
            
    
        
            Schools
        
            工学部
    
                