Contents Menu

Harada Naoyuki

Affiliate Master Yamaguchi University

AC losses with long time constants in a large CIC superconductor

Memoirs of the Faculty of Engineering, Yamaguchi University Volume 52 Issue 2 Page 101-105
published_at 2002-03
A030052000202.pdf
[fulltext] 938 KB
Title
大型CIC 超電導導体の長時定数交流損失
AC losses with long time constants in a large CIC superconductor
Creators Hamajima Takataro
Creators Shimamura Hiroshi
Creators Kakusho Youhei
Creators Tsuda Makoto
Creators Harada Naoyuki
Source Identifiers
Creator Keywords
AC loss coupling loss cable-in-conduit twist pitch long time constant
A large superconducting coil wound with Cable-in-Conduit (CIC) conductor caused an additional AC loss which cannot be estimated from short conductor sample test results. It was confirmed that the additional AC loss was generated by long current loops in the CIC conductor. We propose a mechanism forming the long loops. If one strand on the surface of a sub-cable contacts with the other strand on the surface of the adjacent sub-cable, the two strands must encounter each other again at LCM (Least Common Multiplier) distance of all staged cable pitches and thereby result in forming a pair of a long loop. The long time constants of long loops were calculated. We orderly labeled all strands in a real CIC conductor, disassembling carefully the cable after peeling the conduit. It was found that the strands in a triplex were widely displaced from their original positions, and thereby their contacting lengths became longer than calculated ones. This fact makes the time constant of loop longer and hence can explain the observed long time constants.
Subjects
工学 ( Other)
Languages jpn
Resource Type departmental bulletin paper
Publishers 山口大学工学部
Date Issued 2002-03
File Version Version of Record
Access Rights open access
Relations
[ISSN]1345-5583
[NCID]AA11422756
[isPartOf] [URI]http://memoirs.lib-e.yamaguchi-u.ac.jp/
Schools 工学部