A Comment on Calculation of Feulgen-DNA Content Determination by Microspectrophotometry
        山口医学 Volume 19 Issue 1
        Page 9-18
        
published_at 1970-03
            Title
        
        顕微分光測光法による Feulgen-DNA 定量値の算出法に関する一考察
        A Comment on Calculation of Feulgen-DNA Content Determination by Microspectrophotometry
        
    
                
                    Creators
                
                    Tomonaga Susumu
                
                
            
            
                
                    Creators
                
                    Teranaka Masaki
                
                
            
            
                
                    Creators
                
                    Ogata Hiroaki
                
                
            
            
                
                    Creators
                
                    Nomura Akito
                
                
            
            
                
                    Creators
                
                    Kato Seiji
                
                
            
            
                
                    Creators
                
                    Awaya Kazuhiko
                
                
            
    
        
            Source Identifiers
        
    
        The relative values of DNA contents of lymphocyte nuclei were estimated by the scanning method of Feulgen microspectrophotometry. The caluculation were made by the following two formulas Q_a = ∫| x | f(x)dx (a)  Q_b = r/2 ∫f(x)dx (b) where Q_a and Q_b : the relative value of DNA content f(x) : the curve obtained actually tracing the nuclear along the diameter with the spot light |x| : a distance from the center of the nuclear diameter r : the radius of the nucleus. The values were calculated from the areas surrounded by the extinction curves in the formula (b), and from the volumes of the rotating body of the extinction curves in the formula (a). The calculation from the formula (a), which was recommended by Seno and Utsumi, has been proved very useful in minimizing the distribution errors and the Schwarzschild-Villiger effect. But it is so cumbersome in its practical use that a simpler and dependable method is desirable. We have found that the formula (b) fits for this purpose and the values calculated from it is fully reliable as a result of statistical analysis.
        
        
            Languages
        
            jpn
    
    
        
            Resource Type
        
        journal article
    
    
        
            Publishers
        
            山口大学医学会
    
    
        
            Date Issued
        
        1970-03
    
    
        
            File Version
        
        Not Applicable (or Unknown)
    
    
        
            Access Rights
        
        metadata only access
    
    
            Relations
        
            
                
                
                [ISSN]0513-1731
            
            
                
                
                [NCID]AN00243156
            
    
        
            Schools
        