Evaluation of Preventive Measures to Counter Vibration Disease in an Iron Foundry
        山口医学 Volume 29 Issue 3
        Page 163-168
        
published_at 1980-09
            Title
        
        鉱物工場における局所振動障害予防対策の労働衛生学的評価
        Evaluation of Preventive Measures to Counter Vibration Disease in an Iron Foundry
        
    
        
            Source Identifiers
        
    
        Some preventive measures to counter vibration disease in an iron foundry were investigated. The servo-arm with a servo-mechanism for the portable vibrating tool was developed and introduced. Vibration acceleration level, noise level and dust exposure level of servo-arm equipped chipping-hammer were reduced by 25 to 30 dB, about 10 dB and three fourth respectively, compared with the chipping-hammer operated directly. This servo-arm reduced also the temporary shifts of vibratory sensation threshold and pinching power during the operation time. The polishing room with a local air exhauster 150 m^3/min) and two infrared lamps (3kw×2) were set up in the foundry…
        
        
            Languages
        
            jpn
    
    
        
            Resource Type
        
        journal article
    
    
        
            Publishers
        
            山口大学医学会
    
    
        
            Date Issued
        
        1980-09
    
    
        
            File Version
        
        Not Applicable (or Unknown)
    
    
        
            Access Rights
        
        metadata only access
    
    
            Relations
        
            
                
                
                [ISSN]0513-1731
            
            
                
                
                [NCID]AN00243156
            
    
        
            Schools
        
            医学部
    
                