3rd Report (An Experimental Investigation of Free Convection Cooling of Electronic Equipment)

Memoirs of the Faculty of Engineering, Yamaguchi University Volume 36 Issue 1 Page 51-59
published_at 1985
KJ00000156575.pdf
[fulltext] 511 KB
Title
第3報放熱経路による熱計算(電子機器の自然空冷に関する研究)
3rd Report (An Experimental Investigation of Free Convection Cooling of Electronic Equipment)
Creators Miyamoto Masahide
Creators Katoh Yasuo
Creators Sakata Masaichi
Source Identifiers
An experimental study of free convection cooling of electronic components on PWB, which was placed horizontally in the cabinets, was carried out using the following two types of model cabinet. (1) The cabinets (200×150mm in cross section, 80mm high), which were made of acrylic resins plates (4mm thick), had the ventilating small holes in the top panel and the bottom panel of them. (2) The two-dimensional models of the cabinet (160×380 m in cross section and 80 m high) had many slits in the top panel of them. Numerical values of velocity of the ventilation, which were estimated by the heat balance analysis using the measured temperature, agreed with the values directly measured by LDV. It was demonstrated that the flow rate of ventilation could be estimated using the obtained relation between the ventilating air velocity and the mean temperature excess on the inner wall surface of the cabinets.