Hattori Yukio
Affiliate Master
Yamaguchi University
A Sensitive Method for Detecting Sudunit Dissociation of Abnormal Hemoglabin
The bulletin of the Yamaguchi Medical School Volume 30 Issue 1
Page 11-19
published_at 1983-12
Title
A Sensitive Method for Detecting Sudunit Dissociation of Abnormal Hemoglabin
Source Identifiers
Creator Keywords
Abnormal hemoglobin
Subunit dissociation
Dissociation of abnormal hemoglobin (HbA) by gel permeation employing Sephadex G-75 column. Equimolar solutions(5чM)of Hb A and an abnolmal hemoglobin in 0.01 M phosphate buffer, 7.00 containing 0.09 M NaCl and a trace amount of KCM, are introduced into the column (1.0×60 cm,upward flow) by a peristatic pump (flow rate 0.25 ml/min) one after another. The absorbance at 280 nm or Soret band of the effluent is continuously monitored. The difference in the degree of dissociation is detected by the change in the absorbance at the interface where the two hemoglobins meet. The method developed here has been applied to fifteen different abnormal hemoglobins; twelve of them (80%) have shown either accelerated or reduced dissociation. The method is highly sensitive and specific for the detection of abnormal hemoglobins.
Languages
eng
Resource Type
departmental bulletin paper
Publishers
Yamaguchi University School of Medicine
Date Issued
1983-12
File Version
Version of Record
Access Rights
open access
Relations
[ISSN]0513-1812
[NCID]AA00594272
Schools
医学部