コンテンツメニュー

Influence of Internal By-path Flow on Collection Efficiency of an Electrostatic Precipitator

Memoirs of the Faculty of Engineering, Yamaguchi University Volume 35 Issue 2 Page 251-258
published_at 1985
KJ00000156553.pdf
[fulltext] 606 KB
Title
電気集じん装置の内部バイパス流が集じん率に及ぼす影響
Influence of Internal By-path Flow on Collection Efficiency of an Electrostatic Precipitator
Creators Fujimura Kensuke
Source Identifiers
In order to calculate the collection efficiency in an Electrostatic Precipitator (EP), it is necessary to take into account the effect of gas-sneakage which pass through the upper and down side of effective collection space. There have been reports on the calculation of the collection efficiency with the effect of gassneakage. However, since the calculation method used in these reports is relatively complicated and needs to input the dust particle-size distribution, in practice it is difficicult to apply the method easily. In this paper, the effect of gas-sneakage on the collection efficiency in EP is calculated on the base of new corrected formula of Deutsch's equation, which gives collection efficiency over the wide range of specific collection area (SCA), by using the apparent migration velocity of dust particle for parameter. The results of calculation are graphed and the several impotant characteristics related to the effect of gas-sneakage on the collection efficiency are explaned by the examination in these graphs.
Subjects
機械工学 ( Other)
Languages jpn
Resource Type departmental bulletin paper
Publishers 山口大学工学部
Date Issued 1985
File Version Version of Record
Access Rights open access
Relations
[ISSN]0372-7661
[NCID]AN00244228
Schools 工学部