コンテンツメニュー

Discussion on plastic strain measurements and an application of the developed scribed circle method to shear strain measurements of a micro-surface

Memoirs of the Faculty of Engineering, Yamaguchi University Volume 31 Issue 2 Page 291-298
published_at 1981-03
KJ00000156366.pdf
[fulltext] 1.04 MB
Title
塑性ひずみ測定法の検討と微小域のせん断ひずみ測定
Discussion on plastic strain measurements and an application of the developed scribed circle method to shear strain measurements of a micro-surface
Creators Takimoto Akio
Creators Touge Mutsumi
Source Identifiers
The best method, avairable at present, of measuring the largest plastic strain in the smallest area of a specimen surface is discussed on the developed scribed circle method presented in the previous report, the strain gage method and three different X-ray methods of diffraction profiles, Debye films and the residual stress measurement. The developed scribed circle method is found to be the best one among the above. The application test of this method to measure large shear strain in a micro-surface was performed on a thin walled tube specimen of aluminum. Shear strain of nearly forty percent was measured with sufficient accuracy and that of nearly ninety percent was possibly obtained within a five percent off the condition of pure shear.
Languages jpn
Resource Type departmental bulletin paper
Publishers 山口大学工学部
Date Issued 1981-03
File Version Version of Record
Access Rights open access
Relations
[ISSN]0372-7661
[NCID]AN00244228
Schools 工学部