フルテキストURLA050065000301.pdf ( 863.3KB ) 公開日 2019-03-11
タイトルOptimal balloon size in balloon aortic valvuloplasty : results from a retrospective analysis of multi-slice computed tomography
作成者Nishimura, Takashi
Okamura, Takayuki
Tateishi, Hiroki
Fujimura, Tatsuhiro
Oda, Tetsuro
Wada, Yasuaki
Okuda, Shinichi
Omuro, Ayumi
Maeda, Takako
Hamada, Yoriomi
Nanno, Takuma
Fukui, Go
Yamada, Jutaro
Yano, Masafumi
作成者ヨミニシムラ, タカシ
オカムラ, タカユキ
タテイシ, ヒロキ
フジムラ, タツヒロ
オダ, テツロウ
ワダ, ヤスアキ
オクダ, シンイチ
オムロ, アユミ
マエダ, タカコ
ハマダ, ヨリオミ
ナンノ, タクマ
フクイ, ゴウ
ヤマダ, ジュタロウ
ヤノ, マサフミ
作成者別表記西村, 傑
岡村, 誉之
立石, 裕樹
藤村, 達大
小田, 哲郎
和田, 靖明
奥田, 真一
小室, あゆみ
前田, 貴子
濵田, 頼臣
南野, 巧真
福井, 剛
山田, 寿太郎
矢野, 雅文
作成者所属山口大学大学院医学系研究科(医学)
内容記述(抄録等)Balloon aortic valvuloplasty (BAV) is a bridging therapy for surgical aortic valve replacement and transcatheter aortic valve implantation. Multi-slice computed tomography (MSCT) area-derived aortic annulus diameter was measured retrospectively to determine whether its use can improve the acute gain of aortic valve area compared to echo-derived annulus diameter during BAV. Patients with symptomatic severe aortic stenosis who underwent BAV following MSCT were included in the analyses. All patients underwent evaluations by transthoracic echocardiography before and after BAV. To assess aortic stenosis severity, peak transaortic valve velocity, mean pressure gradient, effective orifice area (EOA), and the Doppler velocity index (DVI) were measured. To assess post-BAV improvement, the ratios of the post-procedural parameters to the pre-procedural parameters, the acute gain ratios, were calculated. Twenty-two patients were analyzable for this study. EOA and DVI improved significantly post-BAV. The optimal cut-off value of the ratio of final balloon size to the MSCT area-derived diameter (B/AREAd) for an adequate DVI increase was >0.936. Frequency of patients with adequate DVI improvement was significantly higher in B/AREAd>0.936 group than that in B/AREAd≤0.936 group (88% vs 43%, p=0.04), with few showing worsening aortic regurgitation. Safe and effective BAV appears feasible using the B/AREAd cut-off value.
本文言語eng
著者キーワードaortic stenosis
balloon aortic valvuloplasty
echocardiography
multi-slice computed tomography
資料タイプtext
ファイル形式application/pdf
出版者Yamaguchi University School of Medicine
NII資料タイプ紀要論文
ISSN0513-1812
NCIDAA00594272
学内刊行物(紀要等)The bulletin of the Yamaguchi Medical School
掲載誌名The bulletin of the Yamaguchi Medical School
65
3-4
開始ページ27
終了ページ35
発行日2018
著者版/出版社版出版社版
リポジトリIDA050065000301
地域区分山口大学
URIhttp://www.lib.yamaguchi-u.ac.jp/yunoca/handle/A050065000301