コンテンツメニュー

D^- density distribution and its dependence on plasma parameters in volume negative ion sources

Thin solid films Volume 506-507 Page 531-535
published_at 2006-05
2007020105.pdf
[fulltext] 567 KB
Title
D^- density distribution and its dependence on plasma parameters in volume negative ion sources
Creators Mori Shigefumi
Creators Fukumasa Osamu
Creator Keywords
H^- D^- density distribution Magnetic filter Plasma parameter control Volume negative ion source
To understand H^-/D^- negative ion formation mechanism, isotope effects of plasma production and H^-/D^- production in volume negative ion sources are studied. Axial distributions of H^- and D^- densities in the source are measured directly by laser photodetachment method. In particular, experimental results concerning dependence of H^-/D^- density distributions on plasma parameters are presented and discussed. Isotope effect of plasma production in H_2 and D_2 discharge is observed. H^- and D^- densities have different spatial distributions, respectively, corresponding to those different plasma parameter conditions.
Subjects
電気電子工学 ( Other)
Languages eng
Resource Type journal article
Publishers Elsevier
Date Issued 2006-05
File Version Author’s Original
Access Rights open access
Relations
[ISSN]0040-6090
[NCID]AA00863068
https://doi.org/10.1016/j.tsf.2005.08.135
[isPartOf] [URI]http://www.sciencedirect.com/science/journal/00406090
Schools 大学院理工学研究科(工学)